Suncenter 100 Psi-10000 Psi Range High Pressure Piston Air Compressor Pump

Model NO.: DGT60
Material: Stainless Steel
Certificate: Ce RoHS
Power: Pneumatic
Standard or Nonstandard: Standard
Trademark: SUNCENTER
Transport Package: 1 Set/Case by Plywood Case
Origin: China
Model NO.: DGT60
Material: Stainless Steel
Certificate: Ce RoHS
Power: Pneumatic
Standard or Nonstandard: Standard
Trademark: SUNCENTER
Transport Package: 1 Set/Case by Plywood Case
Origin: China
Suncenter 100 psi-10000 psi range high pressure piston air compressor pump

Compressed Air Driven Gas Booster Pump- DGA/DGD/DGT Series 

Suncenter Air Driven Gas Boosters provide for pressures up to 80Mpa (11,600 psi). Used for virtually all known gases, these boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging. Key features include: 
 
  1. Compressed Air driven - no electricity required (connect to normal air compressor)
  2. In order to extend the lifetime of the pump, the driving air pressure should 
not be higher than 8 bar
  1. No airline lubricator required 
  2. Hydrocarbon free - separation between air and gas sections 
  3. Pressures to 80Mpa (11,600 psi)  
  4. Wide range of models with different ratios
  5. Built-in-cooling on most models 
  6. Easy to install, operate and maintain
  7. Best price / performance ratio 
  8. No heat, flame or spark risk and explosion proof 
  9. Automatic pressure holding, whatever the cause of the pressure drop, the Suncenter   pump will automatically start, keep the loop pressure constant
  10. Applicable gas: Argon/Helium/Hydrogen/Oxygen/NO2/CH4/LNG/LPG/CNG/FM200 etc.

Applications for Air Driven Gas Boosters
SUNCENTER Air Driven Gas Boosters provide for pressures up to 80Mpa. Used for oil free compression not only of air or Nitrogen, but also flammable and risk gases like hydrogen, oxygen and natural gas. These boosters are ideal for increasing gas pressure, transferring high pressure gas, charging cylinders and scavenging.

Air driven boosters are an efficient alternative instead of electrically driven products and can be used in explosion- proof areas.

As a result of the wide range of models it is possible to select the optimum booster for each application. Single stage, double acting or two stage boosters or a combination of these models can be used to achieve different operating pressures and flow capacities. 

SUNCENTER Air Driven Gas Boosters are ideal and widely used for hydrostatic and burst testing for valves, pipes, tubing and pressure vessels; Calibration for safety valves; Automobile regulator detecting and telecommunication cable inflatable appliances. 
      
                       
Applications 
 
  1. Pressure test with gas
  2. Gas transfer and filling
(Argon/Helium/Hydrogen/Oxygen/Nitrogen/CO2/NO2/CH4/LNG/LPG/CNG/FM200 etc.)
  1. Charging of gas cylinder and accumulator with nitrogen
  2. Supply for isolating gas systems
  3. Gas assisted injection molding
  4. Transfer of oxygen cylinders
  5. Charging of breathing air bottles
  6. Leak test 
  7. Hydrostatic Testing for valves, tanks, pressure vessels, pressure switches, hoses, pipes and tubing, pressure gauges, cylinders, transducers, well casings, BOPs, gas bottles and air craft components
  8. Safety valve adjusting 
 
Suncenter 100 Psi-10000 Psi Range High Pressure Piston Air Compressor Pump



DGA series gas booster pumps(Single acting, single air drive head): 
DGA pumps are available with high quality seals, which provide significantly better service life as well. Pump head fitted with exhaust cooling devices. All parts in contact with the gas are made of stainless steel.



Suncenter 100 Psi-10000 Psi Range High Pressure Piston Air Compressor Pump


 
Model Pressure boost ratio Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure  PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
DGA02 2:1 1.0 16 16 2bar-8 bar 2X PL 1/2 / 1/2 960 (at PA of 6 bar )
DGA05 5:1 0 40 40  2bar-8 bar 5XPL 1/2 / 1/2 680(at PA of 6 bar )
DGA06 6:1 2.0 48 48 2bar-8 bar 6XPL 1/2 / 1/2 360(at PA of 10 bar )
DGA10 10:1 3.5 80 80 2bar-8 bar 10XPL 3/8/ 3/8 210(at PA of 10 bar )
DGA25 25:1 7.0  200 200  2bar-8 bar 25XPL 1/4/ 1/4 120(at PA of 20 bar )
DGA40 40:1 10 320 320 2bar-8 bar 40XPL 1/4/ 1/4 200(at PA of 40 bar )
DGA60 60:1 20  480 480  2bar-8 bar 60XPL 1/4/ 1/4 180(at PA of 40 bar )
DGA100 100:1 25 800 800 2bar-8 bar 100XPL 1/4/ M14X1.5 136(at PA of 40 bar )
Technical spcification
Note:  PL: driven air pressure   PA: gas inlet pressure   PB: gas outlet pressure  
In order to extend the lifetime of the pump, the driven air pressure should not be higher than 8 bar
DGD series gas booster pumps(Double acting ):
DGD series pumps are double acting, with single air driven heads type.   
  1. DGD pumps are available with high quality seals, which provide significantly better service life
  2. Double pump heads with exhaust cooling devices. 
  3. All components in contact with the gas are made of stainless steel. 
  4. Pipes mounting way are available as customized. 
Suncenter 100 Psi-10000 Psi Range High Pressure Piston Air Compressor Pump

 
Model Pressure boost ratio Min. gas
Inlet pressure
PA (bar)
Max.gas
Inlet pressure
PA (bar)
Max. gas
outlet pressure PB (bar)

Driven air pressure  PL
Formula to
calculate gas outlet pressure PB
Connection:
Gas Inlet /
Gas outlet (NPT thread)
Max. flow at driven air pressure of 6bar (L/min)
DGD10 10:1 3.5 80 80  2bar-8 bar 10XPL+ PA 3/8/3/8 410(at PA of 6 bar )
DGD25 25:1 10  200 200  2bar-8 bar 25XPL+ PA 1/4/1/4 396(at PA of 20 bar )
DGD40 40:1 15  320 320  2bar-8 bar 40XPL+ PA 1/4/1/4 320(at PA of 40 bar )
DGD60 60:1 25  480 480  2bar-8 bar 60XPL+ PA

Gas Generator

Energy efficient

Chongqing mechanism co. LTD , https://www.pushgenerator.ltd